422B & 422E

Release Date: December 1 1994
2 Stage Data Process Line TVS Protector

View Datasheet

APPLICATIONS

• Data Processing Equipment
• Long Line Transmission Systems
• Control Processing Computers
• Building Management Systems

FEATURES

• IEC 61000-4-2 (ESD): Air - 15kV, Contact - 8kV
• IEC 61000-4-4 (EFT): 40A - 5/50ns
• IEC 61000-4-5 (Surge): 8/20µs - 95A, Level 4 (Line-Gnd) & 48A, Level 4 (Line-Line)
• Designed for EIA Standard RS-422 Data Lines
• Automatic Reset - Does Not Interrupt Service
• Permanent Two-Stage Line Pair Protection
• Common Mode & Differential Mode Protection
• Subnanosecond Response Time
• Effective Against Lightning, Inductive Switching and ESD

PACKAGING

Package # of Leads Lead-Free RoHS\WEEE Compliant Order Suffix
Custom Module N/A No No N/A
Part Number Stand-Off Voltage VWM
Volts
Clamping Voltage VC
Volts
Peak Current IPP
Amps
Max Current
8/20µs kA/Line
Leakage Current @ VWM
µA
Resistance
Ohms
Capacitance
pF
422B 12.00 24.00 500.00 10.00 5.00 12.000 5000.00
422E 12.00 24.00 500.00 10.00 5.00 12.000 5000.00

Note: tp = 8/20µs waveform. Electrical characteristics per line at 25°C unless otherwise specified.