PAM12SO824
Release Date: December 1 2011
600 Watt Multi-Line Ultra Low Capacitance TVS Array
APPLICATIONS
• Automotive
FEATURES
• AEC-Q101 Qualified
• IEC 61000-4-2 (ESD): Air - 15kV, Contact - 8kV
• IEC 61000-4-4 (EFT): 40A - 5/50ns
• IEC 61000-4-5 (Surge): 24A, 8/20µs - Level 2(Line-Ground) & Level 3(Line-Line)
• 600 Watts Peak Pulse Power per Line (tp = 8/20µs)
• Provides Protection For Two Line Pairs
• Low Leakage Current < 1.0µA
• Ultra Low Capacitance: 3pF Typical
• RoHS Compliant
• REACH Compliant
• IEC 61000-4-2 (ESD): Air - 15kV, Contact - 8kV
• IEC 61000-4-4 (EFT): 40A - 5/50ns
• IEC 61000-4-5 (Surge): 24A, 8/20µs - Level 2(Line-Ground) & Level 3(Line-Line)
• 600 Watts Peak Pulse Power per Line (tp = 8/20µs)
• Provides Protection For Two Line Pairs
• Low Leakage Current < 1.0µA
• Ultra Low Capacitance: 3pF Typical
• RoHS Compliant
• REACH Compliant
PACKAGING
Package | # of Leads | Lead-Free | RoHS\WEEE Compliant | Order Suffix |
---|---|---|---|---|
SOIC: 8 Pin | 8 | Yes | Yes | N/A |
Part Number | Stand-Off Voltage VWM Volts |
Breakdown Voltage V(BR) Volts |
Clamping Voltage VC Volts |
Peak Current IPP Amps |
Leakage Current @ VWM µA |
Capacitance pF |
---|---|---|---|---|---|---|
PAM12SO824 | 2.80 | 3.00 | 21.00 | 30.00 | 1.00 | 3.00 |
Note: tp = 8/20µs waveform. Electrical characteristics per line at 25°C unless otherwise specified.
Series Name | Revision Date | Revision No. | View Datasheet |
---|---|---|---|
PAM12SO824 | May 18 2018 | 3 | Click Here! |
SAMPLE OR BUY
Order, get a quote or free samples directly from ProTek Devices or one of our Representatives or Distributors.
Part Number | Free Samples | Check Stock | Get Quote |
---|---|---|---|
PAM12SO824 |